Component Identifiers

Each piping component from CAEPIPE is exported to PCF in a self-contained data block that consists of a “Component Identifier” together with a list of attributes that help to identify component location, size and specific requirements related to a physical component in a pipeline.
This section provides in details on how each piping component (element) from CAEPIPE is transferred to PCF along with their list of attributes. Each component from CAEPIPE is exported to PCF with Mandatory attributes, Material Information Attributes and Supplementary Information Attributes. The supplementary information attributes of each component will have eight (8) COMPONENT-ATTRIBUTES as shown in the table below.
 
 
Sl. No.
Component Attribute in PCF
CAEPIPE Attribute
English Units
SI Units
1.
COMPONENT-ATTRIBUTE1
Section Outer Diameter
‘inch’
‘mm’
2.
COMPONENT-ATTRIBUTE2
Section Wall Thickness
‘inch’
‘mm’
3.
COMPONENT-ATTRIBUTE3
Section Corrosion Allowance
‘inch’
‘mm’
4.
COMPONENT-ATTRIBUTE4
Section Mill tolerance
%
%
5.
COMPONENT-ATTRIBUTE5
Section Insulation Density
‘lbf/in3’
‘kgf/m3’
6.
COMPONENT-ATTRIBUTE6
Section Insulation Thickness
‘inch’
‘mm’
7.
COMPONENT-ATTRIBUTE7
Temperature T1
‘deg. F’
‘deg. C’
8.
COMPONENT-ATTRIBUTE8
Pressure P1
‘psi’
‘bar’
The co-ordinates for all components and supports are transferred in ‘inch’ for English Units and ‘mm’ for SI Units. Similarly, size attribute is transferred in ‘inch’ for English Units and ‘mm’ for SI Units. The material type and grade for each component is transferred to PCF through ITEM CODE.