Pipeline Header Information
Each “From” node defined in CAEPIPE is exported to PCF as a PIPELINE-REFERENCE attribute with its value set to “P” followed by the From Node number used in CAEPIPE.
The Temperature (T1) and Pressure (P1) defined in CAEPIPE for the element followed by the From node is written to PCF using the attributes “PIPELINE-TEMP” and ATTRIBUTE1 respectively in English or SI units as shown below.
For example, a From Node 10 in CAEPIPE with Temperature (T1 = 200 C) and Pressure (P1 = 10 bar) of the element following the “From” node is exported to PCF as
PIPELINE-REFERENCE P10
PIPELINE-TEMP 200
ATTRIBUTE1 10