Make sure that SST License Manager (SSTLM) program has been installed before installing CAEPIPE LM.

Troubleshooting

Read More

CAEPIPE 3D+

Installation

Read More

It's really important that you review the CAEPIPE 3D+ User's Manual so that you can properly set up CAEPIPE 3D+ within your Plant Design software. This is a step you cannot skip with this software or you won't be able to figure out how to make CAEPIPE 3D+ work properly otherwise. For example, there are some reference field tables that need to be setup initially that will allow CAEPIPE 3D+ to read and interrupt the data out of your Plant Design software.

Troubleshooting

Read More

checkSTRESS

Installation

Read More

It's really important that you review the checkSTRESS User's Manual so that you can properly set up checkSTRESS within your Plant Design software. This is a step you cannot skip with this software or you won't be able to figure out how to make checkSTRESS work properly otherwise. For example, there are some reference field tables that need to be setup initially that will allow checkSTRESS to read and interrupt the data out of your Plant Design software.

* Important note: checkSTRESS is not used independently by loading the program outside of your Plant Design software; instead it is accessed from within your Plant Design software.*

The instructions for installing the activation key are on Page 14 of the checkSTRESS User's Manual.

Troubleshooting

Read More

HOTclash

Installation

Read More

Troubleshooting

Read More

Data Translators

Installation

Read More

Troubleshooting

Read More

SST License Manager (SST-LM)

IMPORTANT NOTE: SST-LM requires .Net Framework 3.5. In Windows 10 and Windows Server R12, please verify that .NET Framework 3.5 is enabled in the "Turn Microsoft features on or off" options setting. For Windows 7 and Windows 8, .NET Framework 3.5 is already installed by default.

Download SST-LM only if it is not installed. Unzip into a temporary folder.

Installation

Read More

Before you get started, please review the SST-LM User's Manual for additional settings or configurations that might be required within your network environment.

Please be sure to install the "setup.exe" file, not the "setup.msi" file. The MSI installer does not work with our SST-LM and will cause an ERROR 2869 if you try to do this.

Please use the option to press the button "More >>" and then "Send email" to email the Product Key to SST's Software Activation Department.

User's Manual

Read More

Deleting Licenses

Read More

Blocking Deletion - Administrator can prevent deleting of product licenses from a remote machine by defining a variable "BlockRemoteDelete=Yes" in the "config.ini" file available in the installation directory of SST-LM.

Troubleshooting

Read More

Error Message: "SST Service is not running." - If you see this error message, please check the SSTLM log file ("C:/Windows/program files (x86)/SSTLM/sstlm.log"). Is the SSTLM service listening to the correct IP address? Make sure that it's not using the loopback IP address of 127.0.0.1 which is only a valid IP for computer troubleshooting and testing. Most times, stop/re-start the SSTLM service will resolve this error.

Stop/Re-Start SST-LM Service - Still having trouble? Have you tried stopping/restarting the SST-LM service? This ensures that the SST-LM environment variables that have been set during installation become activate.

Firewall Help

Read More

Port 12100 - Please ensure port 12100 is open for inbound and outbound traffics on both client and server machines. The SST License Manager service cannot run if port 12100 isn't listening.

Service Help

Read More

Environment Variable Help

Read More

Re-Start SST-LM Service - Always remember to re-start the SSTLM service to activate your modification(s) to the environment variable(s).

Multiple Network Cards - If your computer have more than one network card (e.g., wired and wireless wi-fi connection) then you will need to setup the environment variable "USEIP" to set the primary network card as the "preferred" network card. See instructions on Page 13 of the SST-LM User's Manual for details.

Dynamic IP Address or Work From Multiple Locations (e.g., home/work/client's office) - If your computer has dynamic IP address, then you need to setup the environment variable "SSTLM" to your device name instead of the IP address. However, if you have different work locations, then is necessary to add a new environment variable "SKIPIP" to instruct the SST-LM not to verify the IP address. See instructions on Page 8 of the SST-LM User's Manual for details.

Client/Server Machines Configuration - If you install SST-LM on the server machine, and then install CAEPIPE-LM on the client machine(s), then you will need to manually setup the environment variable "SSTLM" on the client machine(s). See instructions on Page 2 & 3 of the SST-LM User's Manual for details.

Deleting an Environment Variable - please reboot your computer in order for the deletion to actually take effect.